why we r used APFC Panel in industrial area.when P.F. low
then wat will be the effect in our system?
Answer Posted / vivek
if we increase the pf as unity we get healthy power and no harmonic present ion that system. so that losses is decreses and our equipment runs up to full efficiency. so that we reduce the tarrif.and finally save electricity save money..
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
what is the star delta connetion and how can do it a three phase motor with control witing with picture
why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?
33kv substation lay out details & line to line & line to earth measurements
State ohm’s law?
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?
How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.
y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
how can maintaince the acb contactor moveing and fixing kit
how to carried out DAR test in 11 KV Alternator ?
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
What willbe change in programming when we use 5/3 solenoid inplace of 5/2 in operating of a cylinder?