What happen if 200KVAR capacitor continuesly connected to
load and all the plant machinaries are not in working?
Answer Posted / rk gupta
If capacitor is permanently connected to off machinery load then voltage will lead than current. then other equipment's might be damaged due to increasing of voltage.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
which is the most advanced form of SF6 BREAKER?Can we use other gases to quench the arc?
i completed my DEEE. and i want to electrical c license. how to get it..?
i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.
In CTs tan delta point should be earthed , what is the reason behind it?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
If more than rated DC voltage appears across trip coil of the breaker, what will happen? e.g. in 110V DC circuit system, if voltage across battery terminal showing 121 V
Can Anyone suggest the Standards (IEC or IS) for selecting copper current density?
How to prepare electrical preventive maintenance plan & shedule of machine tools in manufacturing unit.
I need the recommended size for a 3 phase transformer at 13.8 KV Primary and connected loads of 3000 kVA at 4200 volts and 2375 kVA @ 480 volts AC.
What is the efficiency during maximum power transfer?
How to select a contactor? How many types of contactors are available
A generating system will have a total capacity of 300 MW. Find the probable forced outage when the capacity is supplied by two 150 MW units. The operating probability of all units is P=0.98 and forced outage probability rate Q =0.02 .
is ac supply can store
hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...
What is core CT & it's function?