Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference between directional earth fault and
non-directional earth fault

Answer Posted / manesh s

Directional Earth Fault is the Fault(between Phase/s to
Earth)in the system,if system is using only one source, so
Fault would be in one direction(towards the system)
where as Non-Directional Earth Fault is the
Fault(between Phase/s to Earth)in the system,if system is
using two or more source, so Fault would be in two
direction(away or towards)

Is This Answer Correct ?    9 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is difference between secondary Air & Tertiary Air and Their use.?

2003


what is natural frequency of turbine shaft .

2294


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1912


By any way can we increase the B check hours from 300 to 500

2195


Why superheated are started before I'd and rd fan?

2181


What is LB-SR.

3001


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2436


what is the meaning of SST300 V56A in SIEMENS turbine

4357


what's the moog valve

1506


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1005


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

2002


why do you consider yourself a suitable candidate for this position

7446


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

3404


LAPT working in alternator / generator

3622


procedure of how to generate power in solar plant.

1952