Pls anyone explain
me the basics of
wiring a house?
Answer Posted / jumaa errfadi
for lamps you can use 1.5mm wire .
for ordinary sockets in rooms use 2.5 mm ((but the supply
wire from mains switch to distribution box should be 4 mm ))
for kitchen ,A.C , water heater use 4mm wire ..
this is in short .if you need mor info. write me .
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is the voltages using in movie theaters??? why ??why not other??
as a electrical student why should i hire you?
why need to be maintain power factor for industrial customer?
DG cranking voltage?
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
How Can you do Maintenance of ACB of 2000Amperes
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformerÂ
Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?
Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit