how to check control valve was passing?how to check online?

Answer Posted / satya

give 100 % close command to cotrol valve if u phsically check valve is 100 % close the open the downstream drain valve if proces fluid comes then valve is passinf . if theie is flow transmitter before cv u can also check

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calibrate Toxic gas detector?

1236


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

1718


describe flow nozzel principle?

2077


Do you have reference list?

1423


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1446






How process line mpm calculation is done?

846


Please can anybody help for control valve sizing step by step procedure?

1638


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

4265


defination of radial vibration?

1672


State some of balance principle’ advantages?

651


what is zero and span ?

1204


how works encoder in plc

1586


how to measure oxygen which methods are using?

1476


please send data bank of quetions answers on analytical instrumentation.

1461


all questions related to instrument technician in any offshore oil and gas company.

20962