Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why tan delta test is carried out in the power transformer?
which parameter are measure?

Answer Posted / saurabh patel

In power transformer Generally TanDelta Test is carried out To Measure the Insulation Resistance of the Bushing of Transformer ,But You would have Doubt there IR is measures also by a MEGGER but Megger actually (Generally ) as 5KV DC in but in this megger The Insulation is Only Measured But In actually in Tan delta test The Insulation. property of Insulator which have a Capacitance Effect When In Loading Therefore this is Taken out to measures the Loss angle of Dielecrtic . Which is Delta (loss angle of Diectric material) .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1809


Why the cores of large transformers build up of circular cross section?

2223


1hp= how much rpm

2019


With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.

1901


WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME

1823


what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks

1830


What is the unit of attenuation?

1006


What is the types of HT motor testing

3486


why is a power transformer used only occasionally?it is used to step up at generating stations?and that needs to be done all day long !!!!!!!

1814


Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1821


How to select a contactor? How many types of contactors are available

3198


HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?

2053


Comment on the working principle of operation of a single-phase transformer.

1130


How Can you do Maintenance of ACB of 2000Amperes

2008


a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn

1487