how do u convert date in 20-12-07 to dec-20-2007 or 20-dec-
2007 or 20-dec-07 in parallel
Answer Posted / shar
First see what is the default date format of the project.
Generally it would be “%yyyy-%mm-%dd”
Then u need to change it to ur required format like :
“%dd-%mm-%yy”
Since the year is 2 digit year then u will have to mention
its four digit year before yy because datastage cannot
understand the latest and old year and it simply consider
year from 1900 century on wards.
So u will have to mention at ur job properties under default
at date as : “%dd-%mm-%2000yy” (must) without which
datastage will not consider u r given date format in
transformer stage date function and it simply go with the
Project’s default date format.
And also mentioning “%dd-%mm-%2000yy” format at job
properties and not mentioning “%dd-%mm-%2000yy” at
transformer stage also works fine.
Ex: if your date is (20-12-07,”%dd-%mm-%yy”) then datastage
consider default date format at job properties and will go
accordingly. And output will be 20-12-2007. And if
“%dd-%mm-%yy” is mentioned at job properties and u have
mentioned (20-12-07,”%dd-%mm-%2000yy”) then datastage will
not consider ur date format and simply it gives the output
as 1907-12-20.
So it is a good practice to see the default date format
assigned to the project and make changes accordingly and
attempt to do the process with it.
DateToString(StringToDate(DSLink3.date,"%dd-%mm-%2000yy"),"%mmm-%dd-%yyyy")
- dec-20-2007
DateToString(StringToDate(DSLink3.date,"%dd-%mm-%2000yy"),"%dd-%mmm-%yyyy")
-20-dec- 2007
DateToString(StringToDate(DSLink3.date,"%dd-%mm-%2000yy"),"%dd-%mmm-%yy")
- 20-dec-07
Now That’s what I call it cooooll.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
How to read the length of word in unix?
DB2 connector> transformer > sequential file Data will be exported into a csv format in a sequential file. This file will be send in a email using a sequence job. Problem here is, how to avoid sending a blank csv file? When I ran the job there are chances that it might return zero records but in the sequence job csv file is going blank. how can I avoid this? thanks
What is the use of datastage director?
Is possible to create skid in dim,fact tables?
On which Dimension Table you implemented SCD Type in your Project
Can you explain kafka connector?
How to clean the datastage repository?
What are stage variables, derivations and constants?
What are the processing stages?
How do y read Sequential file from job control?
explain about completely flow of sequencers technicaly,without using example??explain about lookup,nullhandling?
Explaine the implimentation of scd's in ds indetail, please send me step by step procedure to perform scd's 1,2,3. Please replay for this, Thanks in advance
What are the job parameters?
Why do we use link partitioner and link collector in datastage?
I/p : F1 table have A,B,C,D,E and F2 table having C,E,V i need output 0utput1: ABD output2: V any one suggest me this