Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between 3,4 wire RTD sensor?

Answer Posted / ng

there is lead resistance compensation in 3 wire RTD, where as 4 wire RTD is idle of lead resistance compensation as 2 wires are used for volt measurement and 2 wire for current measurement.there is no question of lead resistance error, it gives accurate result

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Describe a time when you anticipated potential problems and developed preventive measures.

2912


how to calculate control valve bonnet size?? or how to select its material?

2431


How ejector(or)evactor air pump is working in thermal power plant?

6597


Give 2 application of quartz crystal used for process parameter measurement.

2012


how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i

1259


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

2278


What is instrumentation measurement?

1108


how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???

2404


Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1532


What is Positive Calibration and Negative Calibration?

2242


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

2201


What is hp & mp seperator .& what is its working principle ?

2628


pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)

2257


What is eddy current? Describe the operating principle of proximity probe.

2298


What is shielding effect?

2239