Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the deffrence between Siemens S7-300 & S7-400 PLC?

Answer Posted / taj

Siemens rates the S7-300 as a medium level PLC, and the S7-400 as a high-level PLC. So there are differences in work memory, processor speed, number of communication links and I/O connectivity.
First point, the S7-400 family is rack-based (Multi-pin backplane linking all modules, from power supply to I/Os) whereas the S7-300 is a bus-linked platform (a serial connector links all modules). So essentially the physical layout limits the S7-300 back[plane exchanges to MPI speeds (187,5 Bits per second), whereas the S7-400 uses parallel connections over the backplane rack, permitting higher exchange rates, and a higher module-density.
Second point, the form factor of the S7-300 is smaller, more compact than the S7-400, so this is something to take into account if space is a premium (inside a small machine panel, for example).
Now, the higher S7-300 CPUs (especiatlly for the new S7-317 and S7-319)have specs that approach (and sometimes pass) the specs of lower end S7-400 CPUs, so the distinction is starting to blur.

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

2002


is there any lightning by passer is arranged in ship like buildings?

1993


Why we find the sensitivity for the CT's to check?

1915


How will you define capacitance?

1218


I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA

3304


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

2015


Basic motor transformer generator

1541


What does the letter CTNM in negative phase sequence relay means?

1872


can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?

3330


How to test IR testing & magnetic balance test

2040


Differenciate between circuit wiring and sub main wiring with illustrations

2293


How does a transformer contribute towards the widespread popularity of ac system over dc?

1165


1. what is usage for power factor in industries?? 2.why we need to monitor power factor??

8390


What is the difference between amorphous core transformer and CRGO core transformer?.

3792


i have to install a HT panel, what components, I have to use in this and what will the diagram of that diagram,please tell me each and everything.

1845