If i want use the 6 kg/cm2 pressure gauge then how to
calculate its pressure gauge range?
Answer Posted / carl_ellis
The general rule of thumb is to put the working range in at
the mid-range of the scale of the pressure gauge.
Remember, a bourdon tube is damaged beyond repair when
overpressurized.
Alternative rules are
If the working Range is
- Steady: the working range can be 3/4 of full scale value
- Fluctuating: the working range should be 2/3 of full
scale value
- Full scale value: the gauge is working near its limit.
Short duration at full scale value is advised. Replacement
with a higher range gauge is advised.
Typical standard dual scale gauge dial ranges are shown below:
kg/cm2 psi
0-1.06 0-15
0-2.1 0-30
0-4.2 0-60
0-7 0-100
0-10.6 0-150
0-11.0 0-160
0-14 0-200
0-21 0-300
0-28 0-400
The 0-11 bar-Kg/cm2 range puts a 6 kg/cm2 working value just
above mid range.
Yeah, yeah, I know. 1 bar is not exactly 1 Kg/cm2 but we're
talking mechanical gauges here.
Carl Ellis
Measure First
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is instrument philosophy
how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i
what is the difference between -24 : +24 & 0:24 and where it use?
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
Explain bernoulli’s theorem. State its application.
Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection
i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
can you send remote seal interface level transmitter calculation steps for oil water saperator.
Explain the difference between plc and cnc?
Operational amplifiers
Exothermic reaction./ endothermic reaction
if in a level tx height is given, how u calculate the ranges of the tx?
what is The specifications for oriface instalation
What is difference between ESD and PLC please Explain me clearly.