What should be value of Circuit breaker operating time and
tripping time?

Answer Posted / vijay mali

Generally the operating time of the circuit breakers
depends on the designer. The opening time of the breaker
should be less than the closing of the breaker. Opening
time should be less than or equal to 20msec (preferrable).
Closing time depends but preferrably less than 90msec

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1130


what is inverter and converter

1428


describe the Tranformer testing procedure

1458


write a c++ code that receives an integer number and display the sum of the number and its revers integer?

1565


how is the magnetic current test is different in delta-star and delta delta transformer.

1667






How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me

1587


ratings of lightning arrester

1615


As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.

1161


Explain dc generator with its types?

630


how we calculate torque ? how we improve it ?where torque will either motor or generator ?

1568


why we permissive overreach in distance protection.where it is applicable to use in long r short lines

2290


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2227


In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?

1637


WHY DO VOLTAGE TRANSFORMERS FAIL DURING EARTH FAULT IN THE DELTA CONNECTED 6.6KV ELECTRICAL SYSTEM

1540


What is the main cause of magnetism?

1579