Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why corona loss is less with negative polarity?

Answer Posted / ashish gupta

Although the density of free electrons around the positive conductor is less as compared to negative conductor but the electrons are highly concentrated around the curved surface of the positive conductor and hence for same energy that has to be dissipated in corona, the activation energy require to enegerize the electrons to take part in corona will be less in case of positive conductor as compared to negative conductor.
hence due to participation of large no. of high energy electrons around positive conductor in corona as compared to negative polarity we can say that corona losses are higher in positive conductor as compared to negative conductor.
Contact: ashishguptaa164@gmail.com

Is This Answer Correct ?    6 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do u analyse protection fault when vcb tripping on load

1702


How would your past experience translate into success in this job?

6944


What are the advantages of hydropower?

1154


Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.

1776


i have applied for the post of RRB section engineering chennai board please send me previou papers and solved answer. my mail id jagarapusrinivas@gmail.com

2011


How many types oil using in transformer ? How many letars using in transformer..?

2151


what happen if the parallel generator phase angle shift by 1 degree in manual mode

2096


What is error of a measurement?

1266


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1939


lamination figures

1924


Cb closed condition if there is a tcs fail whether cb will trip or not

1896


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2275


how we can set the IDMT relay.

2267


how much UPS neutral erath leakage current.

3815


can anyone provide me a amf panel control wiring using ec-2 relay?

2386