How to calculate busbar size & what is the procedure we
make for determine that?
Answer Posted / sraj
no body have given proper ans, there has to be considered all things like material density, resistance, length, width (cross sectional area) etc, so that we can calculate current carrying capacity of busbar.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
what is the size of cable for 15kw motor and 85 meter cable length using with vfd
how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?
HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT
Efficient electrical earthing in hard rock area
A 2083kva AVR was tested, phase to ground shows continuity, what is the implications
What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?
what is allowable ac mixing in dc
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
what is the difference between ups & inverter
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?
What are the types of piano switches?
Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?
How many types of colling system it trformers?
please give me solution to rectify the emi(electromagnetic interference)