Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is difference between MCB,MCCB,ELCB and RCCB?
Brief description and why RCCB is costly?

Answer Posted / g.t.manikandan

MCB is miniature circuit breaker which is thermal operated and use for short circuit protection in small current rating circuit,Normally it is used where normal current is less than 100A,
MCCB moulded case circuit breaker and is thermal operated for over load current and magnetic operation for instant trip in short circuit condition,Normally it is used where normal current is more than 100A.
RCCB is used to detect earth leakage fault.once there is a ground fault in the load side,current from phase will directly pass through earth and it will not return through netural through RCCB,that means one side current is going and not returning and hence beacuse of this difference in current RCCB will trip and it will safe guard the other circuits for fault loads,that why cost of RCCB also costly

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which book to refer in electrical engineering for iocl exam & which book for general english.

2286


What are the basic components of the feedback control system?

1108


What is the function of auadag in a cro?

1183


Pl. give me checklist for installation & commissioning of machine tool.

2349


What are the types of excitation system?

2108


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1725


in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer 

1865


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

2271


How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.

2061


sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)

2105


What happens when ac supply is given as excitation voltage instead of dc supply

3897


which is the best institute for PLC,SCADA,DCS in hyderabad

2422


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

2068


What are the basic component of a cro?

1292


What is the use of iron core in a transformer?

1178