Answer Posted / rajagopal
1.If there is no hp/lp bypass when the turbine is tripped and still boiler will be in service all the generated steam has to to evacuated by opening SH/RH vents.In presence of bypass system even when turbine is tripped we can possible to bypass the steam and dump it into condenser.
2.the major advantage of doing the above is we can maintain the boiler in hot condition with minimum steam generation cold start up and preservation after shutdown is quite difficult.
| Is This Answer Correct ? | 28 Yes | 0 No |
Post New Answer View All Answers
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
procedure of how to generate power in solar plant.
what is the basic use of power plant in equipment
what does mean by kva rating
operation
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
what is the meaning of SST300 V56A in SIEMENS turbine
LAPT working in alternator / generator
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
what is the difference between compensated & normal drum level in boiler drum?
why airtel use + 24 volts and other operators use -48 volt
Why superheated are started before I'd and rd fan?
why do you consider yourself a suitable candidate for this position