Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can I parallel 1 MVA generator with 1kVA Generator? if V, F,
Ph Seq and Ph angles are same

Answer Posted / sunil kumar kr

I feel the question is an imaginary one as normally no such requirement arises. However the answer is yes. Once these generators are synchronised it will share the load based on the droop settings.

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where servomechanism is used?

1038


how to calculate maximum current

2271


How npn and pnp transistor works

1075


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1898


How may I enrol or get admission to your program?

1857


at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?

2071


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

2146


when generator short circuit condition, the current how dissipates. or at short circuit voltage not available then current how can flow?

2148


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1952


What is Auto Mains Failure Panel & Auto Synchronizing Panel

1881


How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

4284


What is line resistance of cable & how it can be measured ?

1438


If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?

2163


why lightning arrestor are made in two stack of insulator but why not cvt

2013


WHAT IS MEANT BY DERATING OF THYRISTOR?

2901