WHAT IS THE MAIN WORKING OF BOILER.

Answer Posted / sachinbaindal48

BOILER IS ALSO KNOWN AS STEAM GENERATOR.IN WHICH THE HEAT IS
PRODUCED WATER IS CONVERTED INTO STREAM.THERE ARE COALS IS
USED AS FUEL.THEN THESE STEAM SEND TO THE GENERATOR AND
GENERATOR IS A DEVICE WHICH CONVERTS MECHANICAL ENERGY INTO
ELECTRICAL ENERGY.

Is This Answer Correct ?    4 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

With N nodes and B branches what will have a network ???

1522


what is controlling card in dcs? how u measure dcs memory?what is bus in dcs?how u know dcs speed n ehternet speed?

1498


HOW TO CALCULATE ACCURACY OF AN INSTRUMENT. WHICH IS COMPITABLE FOR USE.

1801


What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?

1681


What is the working principle of the magnetic meter?

621






Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?

1047


What is the difference bitween control net scaner and device net scaner

2947


where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia

9323


What is the start up procedure of desalter

3036


What are different types of control valves?

685


can u briefly explain aboutan aryton shunt multirange DC ammeter?

2292


why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?

5879


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1442


how pressure transmitter work, what is its principal to measure and how its generate signal. for pressure transmitterinstallation which precautions must be taken ??

1315


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

1240