how to calculate rate analysis for column shuttering
Answer Posted / rustam jamal
Assume Column Size- 1.200x0.300 and Height = 3.000
than Qty for Conc. = =1.2x0.30x3.0= 1.080Cum
Shuttering Area = 2x1.2x3.0=7.20
= 2x0.30x3.0=1.8
Total =9.0Sqm
In 9.0sqm Shutterin 1.08 Cum Conc. req.
so For 1 Cum Shuttering Qty = 8.333
In case of Columns we required 8.33 sqm of shuttering area
in 1 Cum of Concrete
| Is This Answer Correct ? | 88 Yes | 31 No |
Post New Answer View All Answers
how many kg cement & fine sand reqird in one sq meter 1:6 mortar ratio?
What is chemical composion test
how much cement and sand required for 1cum rr masonry
How do you calculate the unit weight of concrete?
What are some facts about concrete?
strength of bitumen concrete with 80-100 & 60-70 grade bitumen
how to calculate the steel in 500yard
Define What is diversion tunnel in a dam?
What is meant by engineering drawing?
A doubly reinforced concrete beam is 25 cm wide and 50cm deep to the centre of tension reinforcement. The centre of compression is steel is 5cm from the compression edge. The areas of the compression and the tension steel are 10.16cm2 and 12.56 cm2 if m=18 and the bending moment at the section is 7,000,000 N-cm. Calculate the stress in concrete and steel.