Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why anti pumping relay is not given to tripping coil of the
breaker? why only to closing coil?

Answer Posted / k.prakashchandra

Closing is on command and tripping is either on command or
auto .You are testing the circuit by closing the CB using
the control switch

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how does directional relay work incase of ac ?

1568


what can be the causes of capacitor start motor having a higher current that its actual

2007


How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator

2111


what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?

5183


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1915


Draw the single line diagram of the power station?

1142


What is grid collapse? what is the reason for it?

2217


what is the meaning of neutral displacement ???

2795


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1842


HOW TO TEST A LIGHTENING ARREST ER ?

2252


Percentage losses in power generation?

3051


diff. between tension mode & speed mode

2392


i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.

2188


In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?

2019


Draw torque - speed curve and load curve of induction motor? mark operating point ?

2122