what is the difference between transmitter and smart
transmitter ?
Answer Posted / palanisamy
Any instrument having self diagnostic feature is called
smart instrument
Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
How to calibrate Toxic gas detector?
Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.
Name different parts of a pressure gauge.
A length of steel pipe is used to carry sea water to a desalination plant. An adequate corrosion allowance must be specified and indicated in the piping specification, which affects the _________________________ of the pipe
How to calibrate Field bus transmitter? procedure ?
please tel me the calibration of pneumatic controler.
who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.
what is the protection system in solar turbine compressor
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com
how we are selecting instuments by differentiating certain instruments in 4 to 20 ma range and certain in 1 to 5 v dc
Reason for capillary type dp level transmitter fluctuation
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?
what is IEC code in cables & how to selecting cables?
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies