what diff. between
earth nd neutral?

Answer Posted / antu paul ekkan joseph

The value of potential(volts) for a balanced polyphase(eg. 3 phase system) is zero volts.But for unbalanced polyphase system the value depends on relative phase shift angle between phases.For single phase system neutral is the normal return path for the load current.But earth is supposed accidental bypassing path for the fault currents(eg. shortckt. current,leakage current,etc. etc..)It might be might not be a p.d b/w neutral and earth depends on the type of distribution system (single phase or poly phase),type of earthing system ie, TN,TNCS,TNS,IT,TT and its connections.

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much minimum insulation required between 11kv/3.3kv transformer windings?

2514


if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.

2070


What is the magnetic field (coil DC ) of Turbo Expander?

2145


hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible

1916


Hi friends, i m electrical engineer i want a cdr for migration purpose so anybody have information about this then send me on jayesh_ee88@yahoo.com.please try to me

1937


please send me last 5 year interview questions

2282


could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com

2165


i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com

2093


IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com

2171


If a current -8+6sin6t is flowing three ammeter, one is a centre zero PMMC meter, one is true rms meter and one is moving iron meter. What are the reading of these three meter respectively?

2321


WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.

2736


i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400

2256


where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz

2228


sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com

1884


What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.

2429