What is the use of NULL meter on AVR panel
Answer Posted / muneeb
NULL meter at balanced/0/NULL position means no difference
in output voltages of AVR & MVR (manual VR. Used for Smooth
tranfer from AVR to MVR during operation.
Is This Answer Correct ? | 18 Yes | 3 No |
Post New Answer View All Answers
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
explain how the third harmonic content of the magnetising current affects transformer design
what does mean by kva rating
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
why do you consider yourself a suitable candidate for this position
what is the difference between compensated & normal drum level in boiler drum?
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
what is restricted earth fault explain in details
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
How do you consider that you can improve and what assistance do you need to achieve this
LAPT working in alternator / generator
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?