Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

SIR MAY I KNOW IF RADAR TYPE LEVEL TRANSMITTER SHOWING IN
THE FIELD 0 % LEVEL AND IN DCS SHOWING 100% THEN WHAT IS THE
CAUSE I CLEAN THE CHAMBER & TAKEN ONLINE BUT ONLY ONCE ITS
BECOME ZERO IN DCS BUT AGAIN 100% SHOWING IN DCS,THEN I
REMOVE THE POWER SUPLLY AND CONNECT IT AGAIN .IS IT OK BUT
STILL IN THE DCS ITS 100% AND ON THE DISPLAY ITS
INITILAZIATION PLEASE HELP ME READRING THIS?

Answer Posted / i.n

Replace Electroninc card of radar.

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

2016


in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.

2005


where cascade loop use ?

1683


How process line mpm calculation is done?

1392


for oil & gas industries which zone is normally preferred? why? give its example?

1974


what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail

2295


Any one can help me to identified, how can we interchange the device in FF

2770


How d.p. Transmitter can be applied to open tank?

1112


Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.

2058


sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.

2445


what is the usage of QDV & VOLUME BOOSTER

2285


Coal mill Instruments Equipments for cement plant And process diagram ?

2907


What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?

3440


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1454


How to calibrate Field bus transmitter? procedure ?

2326