what is the difference between pumpable concrete and non
pumpable concrete
Answer Posted / balamurugan r
In order to pump a concrete using pump machine to place it
in the final position, it should have the following properties,
1.It should be M20 grade or higher
2.It should have high workability say slump value 90-120mm.
3.It should have well graded aggregates and more cement content.
4.Minimum cement content for this kind of concrete will
around 325kg/cum.
| Is This Answer Correct ? | 7 Yes | 3 No |
Post New Answer View All Answers
How to calculate material and labor required for 100 m2 plaster?
What is Refuse Area In High Rise Building ?
1.Fe500 and Fe550 having more yield strength than Fe415.But why are we prefering Fe415.? 2. d^2/162 formula for knowing the steel wt/m apply all these three? Thanks.
Different sizes of Hollow blocks and its weight. Thanks.
What are the strongest shapes in building?
What is the Null Point of chimney in Power Plant
what is the relation between pitch of steel and depth of slab?
in a building why we are using T beams? why can i adopt beam bottom & Top level as same as slab bottom & Top level?
Whats be the minimum foundation depth of multistoried building as per height of building in individual footing?
significance of specific surface area of particles?
. Write a C program to perform following functions:- a. Declare one integer variable of all the storage classes. b. Print all the variables without assigning any values in tabular format. a. The tabular format must contain the variable name, type, storage class and printed value on the screen in RED color.
why building got air crack? if it get in one particular are what is means?
What is the quantity of cement in mix m20 concrete?
In which code the the maximum height of concrete casting has been explained