how many testing use in power transformer?tell equipment
names?
Answer Posted / sudhakar g
HI,
Power transformer is used in Switchyards where it can
supply the voltage from grid to grid and the strutcure of
the transformer is Delta to Delta connection. there is no
stepup or step down in that.
I am taking Electrical desining classes in Bangalore...It
will be usefull for designing as well as site engineers
those who are intrested to go for Electrical
Engineers....we give you indepth knowledge of Load calu,
Cable sizing, Lighting cal, panels, breaker
selection,Autocad drawing....if any body intrested means
pls call to +91-7760362623 or sudhakar28485@gmail.com
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.
PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT?
Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA
How many types oil using in transformer ? How many letars using in transformer..?
In convertor can we use rectifier thyristor in place of invertor thyristor with explain.
when the time of backcharging the transformer three phases only enough or three phase with neutral is must.from these which one is the best one.
Explain the operation carried out in thermal power stations?
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?
How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.
what can be the causes of capacitor start motor having a higher current that its actual
how you will decide the distance between the power transformer and its fencing
What are the main faults of DC generators?
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com