what is AVR and tell principle and working?
Answer Posted / nikhil
AVR is automatic voltage regulator.as the name shows it
regulate the output voltage of regulator. in fact it is a
card that sense the output voltage of a generator and a
signal is giving to an exciter (an exciter is an dc or ac
generator)and thus the excitation is giving to the rotor of
generator.hence it maintains the output voltage of generator
thereby it prevents the overload.
| Is This Answer Correct ? | 11 Yes | 4 No |
Post New Answer View All Answers
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV
the typical output of a solar cell is........
How stabilizer works??
how to read idmt curva
ult of expression 'document.FrmQF.myem
how calculate gd2 of ht motors
How 48-relay (incomplete sequence) functions?
What test must you do before powering up a circuit that you have been working on?
Why we use mho Relay in long transmission line?
What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?
which metal is use in shunt
what is mind in cable
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
Which thing is maximum in RLC circuit at resonance a)power consumption b)inductive current c)capacitive voltage
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?