How to ensure vibration sensor functioning accordingly.With
out using an other sensor.
Answer Posted / dosshoney
TK-3 is calibrator which is having simulation
option.Vibration sensor can be fixed at TK-3 and simulating
from field GAP will be measured on vibration monitoring
system. difference between simulation and measured gap will
be calculated,so entire loop we can check using of TK-3
calibrator
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
full process of gas turbin?
What is the procedure of calibration of Load cell?
What is ultrasonic flowmeter?
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller
use of split range ? where it is used ? in which control loop it is used ?
I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann
What is motion balance principle?
What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?
WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?
how the arrangement of equipments done in control room
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
sir, give me placement papers and interview quistion of birla group company of copper.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.