Hello, im taking an introduction to PLC..and i'm having a
hard time on creating a program for 2 lamps blinking
alternately with this button characteristics:
1.) One push button (starts upon pressing)
2.) Same push button (when pressed again, will pause the
system)
3.) Same push button (when pressed again, will continue the
paused system)
4.) Same push button (when pressed within 2 seconds, will
shut off the system)
Pls..i know this is just a simple problem for you guys..
Answer Posted / r.sundarraj
First draw relay logic and then given 1)connection from one push button connected through relay common point &take o/p in both lamps from NC via. 2)again press the NC button system pause .
3)now holding purpose taken another 1NO,1NC now system will not run
4)final NC o/p connected off delay timer
system power off
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)
what will be the maximum winding temperature of 6.6kv HT motor 450kw, Full load current 49A. 50Hz Frequency.
Percentage losses in power generation?
Is potential difference materials property ..? if yes tnen how.. explain brifly.
What are the Full Forms of TVM, MTL, CVT ?
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
WHAT IS MEANT BY INSULATION CLEARANCE IN VACCUM?
When we connect the large capacitor bank in series ?
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
how to select the isolation tranformer for siemens 802dsl cnotroller
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?
Define ampere
What is cut-off rate?