explain about the electrification in the Indian Railways?
ie., how the power is taken and used to drive the train?
explain with the block diagram??
Answer Posted / guest
25kv AC line normally used, current collector pentograph is
used to collect current then this power transform to a lower
level(voltage) by transformer. now this power is converted to
DC and used to drive DC motors. these DC Motors drive the
train.
25 KV AC supply collected from the Grid and transmitted in the
railway grid along the tracks boosters are arranged at
different section to maintain voltage level.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
How we can calculate the life of Lead acid battery
What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?
TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
WHY IS THE EARTH FAULT CURRENT ALWAYS LESS THAN THE NORMAL CURRENT??
why do we carry out winding resistance test?
How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.
I AM FROM ELECTRICAL ENGINEERING ? I AM ASPIRING FOR "BHEL".HOW I HAVE TO PREPARE .ON WHICH TOPICS TO BE CONCENTRATE MORE.PLEASE GIVE FULL DETAILS OF WRITTEN EXAM.
if 2 coil of 1000W connect in series and 200 v is applied across it . then what is the total power of coil when coil have only resistive load .
The D.C. spark test is applicable to single conductor cable & assemblies of insulated single conductor cables without insulation shield,metallic sheath or metalic armor?
would the same effect be achieved by reversing the connection to one winding of the induction motor 3-phase?
What are the section criteria for cables. Now everywhere XLPE power cable is used or PVC is also used?.
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
Why do we need interlocking in a HT metering or Ring main unit switchgear?
specify the inbuilt protections in DG