what is the full form of KVAR

Answer Posted / niranjan

K-Kilo, V-Volt, A-Amper, R-Reactance

Is This Answer Correct ?    11 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?

1805


i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.

1596


which type of motor is used in automatic swing gate

1567


How to calulate Locked rotor amper(LRA) for compressor type motors?

1283


How to select cable the size, what is the parameters use and what is the formulas use for this cable size calculation?

1406






I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1035


What do you mean by pull of electromagnet?

591


What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1329


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1197


what is 3rd Harmonics? how it is generated in alternator

8448


use of PIR in ehv breaker

1707


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1659


For group 1 , 2 whather i have to prepare my technical or general studies etc? and im graduate in ee engg. for wht posts im eligible for? please tell me!

1721


sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me

1468


i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately

1550