Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What core magnetic balance test of transformer?
How to do this test in a three phase Star delta (star-LV,
Delta-HV) transformer?
How to measure and where to measure?

thanks and regards
Austin

Answer Posted / k kiran kishore

This is kiran kishore from IEMCO MUSCAT

Can any one explain why this magnetic balance test performed
on star side only? is there alternative methods for this
test? in my knowledge 1. phase in method
2. phase out method.

give me the clear idea. can u explain if tertiary winding
also present then how this test going to be performed?

i hope you guys will give me clear explanation to all my
quires.
THANKS&REGARDS
K KIRAN KISHORE

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define what is power quality meter ?

1267


what r PID controllers?why they r used?what is there purpose?plz Explain in detail

2073


What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer

1814


What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.

8284


Why can't we parallel Voltage transformer secondary circuits?

1636


Is any AC drive(VFD) had a feature of DC injection braking? if available please mention the detail. i.e drive can supply braking torque when the motor in idle state.

2145


What is the importance of counter based plan & how is it scheduled?

2012


Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.

2245


What is the criteria for selecting the voltage classes of an AC Induction Motor.The KW rating above/below which ht/lt selection is made may be provided in details.

1648


if a.c supply is given to the motor,, what happen?

2162


What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?

1782


What are the material used for resistor?

1116


what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel

1991


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1975


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1589