Can we connect two or more energy meters/Amp meters on one
CT set(Three phase).
Answer Posted / abhishek pathak
ya why not. Actually always current is flow in series you put on one wire from ct s1 and connect on first energy meter s1 and put on one wire from s2 of first energy meter connect on s1 of second energy meter and second energy meters s2 connect on ct's s2. Then your current path become OK and there will be same rating in twice energy meter which is actual. like this all phase CT will connect on energy meter. and make paralleled of phase voltage line on meter.
| Is This Answer Correct ? | 18 Yes | 0 No |
Post New Answer View All Answers
Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet
why the neutral line is not giving shock to us if we touch it ?
Do inductive loads have distorted current waveforms ?
Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة
What is the minimum value of hfe for the oscillations in transistorized rc phase shift oscillator?
how we provide neutral earth on synchronising panel as per electrical standards?
What are hrc fuses and where it is used?
How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.
sir, Is their any measuring unit of knoking? please explian?
TRAFO 1. WHY BREATHER IS USED. 2. WHY OIL GOES DOWN IN CONSERVATOR TANK. 3. WHY WE ARE TAKING OIL SAMPLE TAKING FROM BOTTOM OF TRANSFORMER. 4. HOW TO CHECK IR VALUE OF TRANSFORMER. 5. WHY OLTC HAVING BUCHHOLZ TRIP ONLY; WHY NO ALARM. 6. OFF LOAD TAP CHANGER OPERATION PROCEDURE. 7. TR. SHUTDOWN / ISOLATION PROCEDURE. 8. WHEN THREE TRS. IN PARALLEL, ONE TR. IS NOT SHARING THE LOAD – WHAT IS REASON AND WHAT YOU WILL DO. 9. WHY TR. HAS OLTC IN HV SIDE. 10. WHAT IS % IMPEDANCE. 11. WHY TR. RATING IN MVA. 12. WHAT IS VECTOR GROUP IN TR. 13. CONDITION FOR PARALLEL OPERATION OF TRS. 14. WHAT IS TERTIARY WINDING. WHERE IT WILL BE. 15. IF TR. TRIP ON BUCHHOLZ OR TAP CHANGER RELAY, WHAT YOU WILL DO. 16. DIFFERENCE BETWEEN OIL TEMP. AND WINDING TEMP. PROTECTION 17. HOW WINDING TEMP. IS MEASURED IN CAST RESIN TR. 18. DIFFERENT TYPES OF FAULTS IN TR. Trafo - Page-1 of 2 19. WHAT HAPPENS WHEN TR. CHARGED FROM LV. 20. WHAT WILL YOU DO IF MEGGER READING SHOWS ZERO BETWEEN LV WINDING AND EARTH. 21. CAN WE INTERCHANGE BUCHHOLZ RELAY OF MAIN TANK AND OLTC TANK. 22. IF THE LINE BETWEEN BREATHER AND CONSERVATOR TANK 23. LOCKED, WHAT WILL HAPPEN DURING LOAD CYCLE. 24. WHAT IS THE FUNCTION OF OIL SEAL IN BREATHER. 25. WHAT ARE LOCATIONS FOR BUCHHOLZ RELAY FIXED IN POWER TR. 26. WHAT ARE CHECKS IN POWER TR. DURING MAINTENANCE. 27. WHAT IS IMPORTANT WHEN WE CHECK OLTC OPERATION DURING MAINTENANCE. Trafo - Page 2 of 2
How to calculate loses in transformer of 160 KVA ?
Define norton equivalent circuit?
work of choke in florocent tube circuit ?
What is MS-EXCELL?
what you have to see after one week or month from the day of installation of transformer ?