Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we commonly use delta star winding in power and
distribution transformers

Answer Posted / a,karthika

because we can make earthing only in star connection.if
there is an excess amount of power which can be easily
removed by earthing.Hense secondary winding is a srat
winding

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Discuss about gear cutting machines.

1203


What is the cut-off rate?

1130


Define settling time.

1150


How do i carry out or know the vector group of a Dyn1 and Dyn5 transformer

2025


What is reverse power relay?

1157


what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.

2084


What is ideal IR values for ground and neutral.

1733


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2101


What are the effects of adding a zero to a system?

1264


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2324


what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.

2066


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

5247


Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.

1657


CAN CU XLPE/PVC CABLE BE USED INPLACE OF LOW NOISE SCREENED CABLE? KINDLY GIVE REASONS

1860


ho can we calculate the conductor insulation value according to their ratings like voltage,current etc.how insulation value related with voltage,current and power of amachine

2067