Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be the sampling point in dissolution test?

Answer Posted / navinpatel

There is no specific recommendation for sampling in
dissolution test. It is recommended that a specimen should
be withdraw from a zone midway between the surface of the
Dissolution Medium and the top of the rotating basket or
blade, not less than 1 cm from the vessel wall.

Where multiple sampling times are specified, replace the
aliquots withdrawn for analysis with equal volumes of fresh
Dissolution Medium at 37°C or, where it can be shown that
replacement of the medium is not necessary, correct for the
volume change in the calculation.

Specimens are to be withdrawn only at the stated times
within a tolerance of ± 2%.

Is This Answer Correct ?    16 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how quantitative stability studies are done?

5882


Discuss the potential side effects and risks associated with Alprazolam usage. How would you manage or mitigate these side effects in a patient?

491


what is the defination of Change Control given in various guidelines?

3080


What is the Disintegration time for Hard gelatin Capsule in USP?

2106


what are all the needs or pre-requisites to perform project on bracketing and matrixing of stability products?

2046


how you can fix the known and unknown impurity limit for any drug substance

3158


What is the calibration of HPLC?

2253


HOW TO PERFORM SATURATION SOLUBILITY IN DISSOLUTION METHOD DEVELOPMENT?

3736


when we calibrate uv for control of wavelength we scan for 200 to 800 nm but we get the result only for some specific wavelength how we confirm for all other wavelength?

2382


What are the advantages and disadvantages of working for a small & big pharmaceutical company?

1100


the international interview procedure for a job.

2297


if calibration of 12 bowl dissolution apparatus does not meet a single stage procedure how you can proceed calibration

2861


what is antioxidant para meters

2752


In dissolution test why sample is withdrawn from top of the paddle and not less than 1 cm away from wall?

2432


What skills would you look for while hiring a pharmaceutical representative?

1011