Why do you get a typical sound when the transformer is put into operation?
Answer Posted / mgalalkhedr
This is normal due to thr inrush current. the sound can be
heared for one to two sec.. some times and according to the
relay settings the transformer may be tripped on over
current and it is normal
Is This Answer Correct ? | 11 Yes | 1 No |
Post New Answer View All Answers
How can I calculate ISF of current transformer?
how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc
WHAT IS THE MEANING OG (li = 7 In)
Please explain, how to test vector group of tranformer(Delta y1) . Thank
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
PLEASE INFORM ABOUT THE IDEAL TEST RESULTS OF MAGNETIC BALANCE TEST OF TRANSFORMER 33/11 kv DELTA-STAR T/F
model question paper for supervisor trainee
what type of earthing do for dry fissure rock?
block diagram of 2 ups system connected in parallel mode?
For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is
which is chemical used as in ro water what is difference betweeen multi grade filter&dual media filter
how to work droop ct in generating station
If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer
I want to calculate how much capacitor we connect to maintain the unity power factor? Is there any formula? Pls give me the answer
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?