Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Air pressure in a pressure vessel can rise or fall at up to 2.5kpa/s.The pressure is
sampled every 0.5 seconds.If range of the the pressure indication is 0 to 1500
kPa, what is the max value of the error due to sampling in % of Span

Answer Posted / markwilcon

Any one able to help??

I have error = 0.5s x 2,5kpa/s=1.25 %

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

give me the formula for analog to digital converter and also d to a converter

2826


Which topics are covered in Process Control?

2138


what about your moleg in pogrees with company

2261


The Design Calculation of Level Transmitter For Different Structure open & Closed Vessel, Eg. Diff. Level Tx., Capacitance For Continous Operation

2840


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5352


What is loop1 and loop2 in MTS LT?

3824


hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?

2091


What is the difference between mmwc and mmwg?

1349


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1386


How an rtd work, and what volts/current goes to a rtd to measure the resistance?

1263


How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System

1345


why we are using drum level control valve air to close?

2080


May I have a brief note above the voltage barriers? Whats is the purpose? Please mail me if you've operational details, mail id: rajkumar.diice@gmail.com

2114


How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?

5890


I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.

2069