Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can we run 3 phase induction motor under 2 phase supply

Answer Posted / engineer bhai

yes we can run induction motor on 2 phase supply there are
three methods
1. first rotate the roter with some externel means and in
running condition of the motor switch on the supply.motor
will start running but in unbalanced and unstable condition.
2. connect a capacitor to one of the phase and give supply
to the motor with two already awailable phases and one with
the capacitor.capacitor will provide required phase
dispacement.motor will be more stable in this connection.
3. use scot connection of transformer to provide 3 phase
supply.

Is This Answer Correct ?    34 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the function and use of cable differential protection relay?

2919


I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)

2137


Why single phase induction motors are not self starting ?

1662


any one can explain what is the size of pvc,armoured, various sizes of powr cable dia?

1927


what is auto re-closer?

2641


After synchronization with grid what is the demand value QKVAR and how we will maintain that?

2273


in shunt clippers why a resistor is used in sereis with the input

2101


i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.

1797


Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain

3037


if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.

1984


what is mean by transition resistance of transformer?

4541


what is harmonics? what are the factors it will depend upon

2032


WITCH CARDS IN USE IN FIRE CONTROL PANEL.

1935


what are the parameters plays a major role in Potential transformer Burden calculation??

2203


why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

5154