can we run 3 phase induction motor under 2 phase supply
Answer Posted / engineer bhai
yes we can run induction motor on 2 phase supply there are
three methods
1. first rotate the roter with some externel means and in
running condition of the motor switch on the supply.motor
will start running but in unbalanced and unstable condition.
2. connect a capacitor to one of the phase and give supply
to the motor with two already awailable phases and one with
the capacitor.capacitor will provide required phase
dispacement.motor will be more stable in this connection.
3. use scot connection of transformer to provide 3 phase
supply.
| Is This Answer Correct ? | 34 Yes | 6 No |
Post New Answer View All Answers
what is the function and use of cable differential protection relay?
I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)
Why single phase induction motors are not self starting ?
any one can explain what is the size of pvc,armoured, various sizes of powr cable dia?
what is auto re-closer?
After synchronization with grid what is the demand value QKVAR and how we will maintain that?
in shunt clippers why a resistor is used in sereis with the input
i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.
Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain
if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.
what is mean by transition resistance of transformer?
what is harmonics? what are the factors it will depend upon
WITCH CARDS IN USE IN FIRE CONTROL PANEL.
what are the parameters plays a major role in Potential transformer Burden calculation??
why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?