Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I want formula to calculate cable size as per load given in
kw & amp.I searched many sites but didn't right answer.Plz
reply me asap.

Answer Posted / santhosh

as one of our friend said above
for Al its 1.2 amps and for Cu its 5.0 amps per 1 Sq.mm
but actually its
1 .0 amp for Al and 8-12 amps for Cu [per 1 Sq.mm].

the basic thing is that suppose a cable for load of 100 amps is to be laid then
for Al 100 amps/3 phases=33.33 amps/phases,

as we don't have 33 amps cable take 36 Sq.mm cable (near and above the value) i.e,3 C*36 Sq.mm.
for Cu consider 8 amps for Cu
then 8 Amps*5 Sq.mm =40 Amps per core or phase

i.e,for 100 amps load u need to lay
a cable Al= 3 Core *36 Sq.mm

and for Cu =3 core *5 Sq.mm

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between electronic regulator and ordinary rheostat regulator for fans?

1026


what is the difference between c power and U power acb breaker

6411


Why GRR starts from 60% of motor speed why not less than 60%?

1702


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1964


what is the voltage rating of chiller unit sensors

2773


How many double suspension hardware fittings are required on a double circuit transmission tower?

2103


Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?

1879


What is the unit of charge and current?

1159


what are the installation procedure of high voltage power transformer,CT,CB&PT?

2063


How one can check the MAIN of a house wiring ?

1968


Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.

1878


Why power factor should not be in leading (capacitive) mode of any load.

7023


whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11

1863


for 11KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV OH system what will be typical per KM "R" "L" "C" parameter. for 33KV UG system what will be typical per KM "R" "L" "C" parameter.

2454


write down the formula of cable size in RM if current is 50Amp.

1340