what is the best method to measuring level in high pressure
and temperture thank?
Answer Posted / vivek gupta
if tank is filled with solid then Nuclear level detector
will be best.That will not come in contact with material so
less maintenance will required.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd
Draw symbols of the following :
Explain the use of hair spring in the pressure gauge.
1. what is modbus cable? 2. what kind of communication we are using for the interface of DCS, ESD and Third party cabinets? 3. What is serial communication and peer to peer communication?
Tell about your IFFCO plant visit.
How earthing can be checked????
I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.
How to erection of DCS Panel at site step by step
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s
how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line
is motorized valve closed when power shutoff?
Calibration procedure for Electro magnetic Flow meter
Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?
What is the diffrence between ff tx and non ff tx