Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have running 4 generator in paralel.All generators
Voltages is same(470 V),KW also same (100 KW) but only No2
generator Amper is high than another generators.
DG No:1,3,4 470V,100KW, 150 A
DG No:2 470V,100KW,400 A

Answer Posted / saad

the power formula P=1.732*VICaso according to that if
current will increase active power will also increase so u
check ur meters once again

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can i connect wavetrap in 2 different phase in EHV line?

1918


what happen as when voltage drop(or may decrease) ? in case of atomic base theory?

2081


What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?

1920


What is Fire Panel ? How it works ?

2119


What is FTA card? How it works?

2280


describe the A.C. Generator Testing procedure

2223


What is vaccum currcuit breaker.define with cause and where be use it device?

1161


What is the difference between amorphous core transformer and CRGO core transformer?.

3792


What information we need to prepare relay coordination chart

2395


dg earth connect only in the amf panel or not why

2140


who can measure the size of power cable?

2205


What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?

2323


Hi,I am working in abroad for more than 3 years in a company operating with 11kv and 6.4 MW power. I need c licence in India,can I? some other says only i can get if i work for 2 years in india only! anybody kindly clarify by doubt.Thanks

1901


Why efficiency of generator is higher than motor at a particular load?

2128


l&t switch FN 63 handle position can we change

2605