1. what is exciting winding, rotor winding, startor
winding. and how it works? in ac generator
Answer Posted / pradyumna chandra panda
Field winding of ac generator is act as exciting winding and it wound in rotor to collect more power from stator (armature)or in stetor where rotor act armature. Intially there is some residual magnet in field winding and gradualy increase with increasing rpm by collect emf from armature stepdowned by 24 volt dc or more. some time it is seperatly excited by a battary or by a dc generator.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
How DC earth leakage currents can be reduced ?
what is the id1 & id2 setting in differential protection relay of CSPC?
The SFC of an engine is 0.25 kg/kW hr. when the fuel used has a calorific value of 36000 kJ/kg. the thermal efficiency of the engine is
how calculate the electrical load for industry and office
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
What do you mean by turns ratio of instrument transformer?
what is the practical application of full adder circuit?
what is meant by skew width in machines?
what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY
List examples of current sources?
where are the circulat the diesel in DG parts name with pictue
HOW DOES THE ELECTRONIC ENERGY METER WORKS?
what is Fan Control Cubicle
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
how much cable size required for 70 kilowatt load.