Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why can't we increase the voltage by increasing the field
voltage in order to get higher voltage.so that we can
eliminate step up transformer

Answer Posted / surendra

In which mode machine is running ,that basiclly tends to
decide the field excitation....apart from this if you
increse the fild excitation to high value saturation
occurs... losses will be more.....

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have finish diploma electronics and five years experience in electrical field in ht service how can i get c licensce or other electrical certificate

1624


HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?

2543


Define noise?

1110


what is conductor copnstant of ab cable

1816


WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.

2146


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1811


What are the advantages of hydropower?

1030


Basic motor transformer generator

1419


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2608


in 132kv substation CRT means

2569


HOE WE CAN IMPROOVE BY USE OF CAPACITOR

1907


PIU how does work?

2380


A jet of fluid strikes a plate What was the force required to counter it?

1822


A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

2538


design of IGBT firing circuit for 11KV

2580