What is the difference between online ups and offline ups?
Answer Posted / mithilesh dwivedi
Online UPS alwaws given Constant voltage i.e.230V 50 Hz.and
what ever input like 170 v to 270V.Voltage goes through the
circuit and through the Battery in any time when AC is
present or on Backup position.
Offline UPS alwaws gives Same output what is input received
from Main. Voltage goes Without Circuit and only Battery
charging Voltage 12V DC goes to battery.When Mains is fail
then supply goes from battery backup.
Resultant On Line UPS Costly than the OFF Line UPS.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the difference between the impedance percent and impedance voltage ?
what is residuel magnetism. and how order lead acid batteries for 24 volt. emergency lighting system.
How grounding is different than earthings?
As i want some model question paper in basic computer science and history please send me immediately sir
WHY THREE PHESE SYSTEM VOLTAGE APPLIED IN 440 VOLT
Which Class insulation is prefered for the sandwich Busducts ? Why?
How to work meggar?
what happen ehen synchronisation is done at below rated speed
what r the checklist while installing 500 kva transformer
What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan
why would amp draw on neutral wire be as much as amp draw on the hot leg.
how we arrange the hv side with delta connection in case 33/11kv of transformer.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
What current flows in the transformer primary when its secondary is open?