what is mean by unity power factor?why are u calling
Resistivity load also unity power factor?
Answer Posted / momenkasiu
Unity power factor means that Pf=1 or cos(phi)=1 so (phi)=0 where (phi) is the angle between the apparent power & active power in the power triangle so it means that the apparent power equals the active power and the reactive power in this case equals zero. No reactive power transmitted between the source and load which it exists only in the case of resistive loads.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?
what is effect of length of air gap on performance of dc motor and generator?
how we calculate the dick for a pole?
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph
why burdens of VTs is more than CTs?
How to synchronization will be done between two DGs ?
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
how many current required for hypo test
1.what is difference between ATS & STS main use. 2.what is difference between ACB& VCB With symobles,and main partes, manimum range. 3.How many types of relays and main function.
How will you utilise electrical power? You can start from the generating station.
Name of the relay of low lub oil presuure in DG sets