Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer calling in VA rating

Answer Posted / rakesh maharjan

The KW rating is dependent on the power factor and power factor can be different depending the condition where as mostly 0.8, but if KVA rating is given we can calculate the KW rating as per our condition. So KVA rating is fixed and reliable to any malfunciton not to occur. so the transformer rating is given in KVA.

Is This Answer Correct ?    4 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is lumped and distributed elements?

1935


what is meant by twilight switches 7 where its applicable ?

1906


Whether the vacuum contactor requires Short circuit protection?If No,why?

2022


Explain the method to keep noises low in a control system?

1114


What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??

1838


draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it

2704


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1954


How will change the frequency in distribution side?

1770


What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.

2660


how can calculate resistance box for 15 kw, 6 pole, RV-230, RA-42 motor

3319


what is the difference between the voltage of 5 volts capacitor and and 5volts battery?

1929


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2312


List out the the types of Mounting Light fixture?

1593


before synchronizing an alternator,power factor is leading ,why?

1554


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2491