Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

transformers parts & function of each parts

Answer Posted / s.m.jalal atta

help oil filling this is situated upper portion of the
power transformer . mainly these are cylindrically
shapped...
2) TANK - basically this is a container used to keep
windings(both) and cooling oil.
3) BUTCHHOLZ RELAY - this is a protecting device used to
protect our transformer windings . this is a double ended
device one end is conneced to conservator other is
connected to tank. there are two windings inside the relay
one for detecting oil level goin to empty and other is
connected to a alarm circuit for warning
4) BREATHER - Breather is a device used for absorb the
moisture content of a oil and sucked air
5) SILICA JEL - it is a chemichal matarial these are the
only one main component inside the breather basically
silica jel is a brown coloured one after the absorbtion
silica jel become pink
6) OIL LEVEL SCALE - this is a ordinary part situated on
the side of the conservator for proper oil checking oil
tank wants a specific amout of oil
7) PRIMARY WINDING - in Power Transformers primary
winding is the main element for external connection
from where the power is connected to thi winding
8) SECONDARY WINDING - is a another winding to reduce
power (for step down purpose)
9) DRAIN VALVE - is used for taking damaged oil from the
oil tank for the proper oil collection this valve is
situated under the oil tank
10) PORCELIN BUSHING - This is a outer unit , this is used
to prevent unwanted leackage of electricity
11) RADIATOR - This device is used to keep the cool oil
(filled oil)

Is This Answer Correct ?    48 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how many single tension hardware are required on a double circuit transmission tower?

1936


how we can calculate chiller required ampear?

2050


define displacement & magnitude ?

1838


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1585


A low wet bulb temperature indicates

1154


substation+ plc system

2070


what is auto re-closer?

2624


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2184


What is resistance of 50meters, 16sq.mm, single core copper cable?

1882


What will be the effect of circulating current in HT xlpe cable when both the armour ends are grounded. Will the termination fils after some time in case of 33 kv supply.

2068


sir, i'm preparing for hpcl exam officer trainee pls tell me how the exam ques paper pls pls

2248


On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?

2647


State norton’s theorem?

1102


what is gridrotor resistance starter

1872


WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING

1784