Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to find earthfault location in long cable layed
underground or outside.

Answer Posted / santoshvarma

You can find the faulted location with the help of multimeter.

Measure the capacitance at both the ends,between faulted
phase with respect to earth.
For one end if it is C1 and for other end it is C2. And
total length of cable is L and Capacitance is C.

Then by using the below formula, you can find the faulted
location

LC=L1c1+L2c2

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

explain with diagram how to protect transformers and substations from over current with help of CT's?

1934


Is it posible to instal one more SMDB from the existing SMDB and is it practical.

2073


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2203


previous year paper of ntpc bhel for degree in electrical enng

3194


why ht cable end termination don't have a gland?

2926


Name the types of motors used in vacuum cleaners, phonographic appliances, vending machines,refrigerators, rolling mills, lathes, power factor improvement and cranes.

1131


Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz

2281


what is the use of expulsition protective gap in 11Kv line.

2114


How the over load setting for HT Motors calculated-provided in Numerical Relay

1798


can i connect the two phases of scott connected transformer,if not why?

1958


What are the main significances of root locus?

1214


What is the tipical Online UPS input voltage for 20 KVA load ( 3 Phase or 1 Phase )? Why ? Explain it...?

2630


can anyone show me how the 3 phase power is supplied to socket outlets?

2001


why would amp draw on neutral wire be as much as amp draw on the hot leg.

2079


Why let through energy not considered for ACB breaker while cable sizing?

2384