Answer Posted / mahesh
IGBT using pulse with modulation
Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
How to see the inductance in a transmission lines
i want to know about torque of slip ring induction motor
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
operation of diesel generator
If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!
Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?
Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.
If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these
there are cam operated switches - why we call cam operated , What is cam ?
How we calculate the Multiplying Factor of Kwh meter for 3 phase alternator.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
i wasted one year for the job after completed my btech what can i say about 1year time in interview
how braking & making capacity of circuit breaker is calculated?
what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?
what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.