Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be cable size for 75KVA 380/220 3ph transformer

Answer Posted / essemmay

thanx raja..is it possible 50mm2 for both side cables..incomer and outgoing of the transformer, since the incomer voltage is 380 and outgoing is 220, so the same size is enough??

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?

1807


how line turns ratio changes in 3 phase with change in connection

1976


what are the accessories need to be added while doing estimation for the following: 1.MCCB 2.MCB 3.ACB

2094


it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?

2016


sir, Is their any measuring unit of knoking? please explian?

1873


why Current is lead 90 degree and voltage is lag 90 degree in a capacitor.? why Current is lag 90 degree and voltage is lead 90 degree in an inductor.?

2261


Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?

1206


what will happen if frequency is below 50 hz?

2021


What are n circles?

1083


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

2254


In dc ckt. 24v or 110v, which one is more efficient and why?

2231


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1875


what is d check in dg 1500kva

2118


WHAT IS MEANT BY INSULATION CLEARANCE IN VACCUM?

1972


testing of Vector Group – YNaoD II

2925