Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be cable size for 75KVA 380/220 3ph transformer

Answer Posted / essemmay

thanx raja..is it possible 50mm2 for both side cables..incomer and outgoing of the transformer, since the incomer voltage is 380 and outgoing is 220, so the same size is enough??

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines

1682


In diesel generator how AVR get voltage to excitation. And basic diagram DG EXCITATION CIRCUIT.

3376


Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.

2221


What is the effect of pi controller on the system performance?

1173


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2166


is it possible to test of bus bar in high rise building without completed full floor ?

1741


What are the properties of a resistor?

1170


What are the special cables required for explosion proof wiring?

16829


how to decide the capacity of accl

2490


WHY IS THE EARTH FAULT CURRENT ALWAYS LESS THAN THE NORMAL CURRENT??

2279


How you give clearance to a spare feeder.

1749


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1987


How one can check the MAIN of a house wiring ?

2022


On what basis the the size of Lightning arrester for buildings are selected ?

1704


whether fibre optic cable in high voltage earth conductor is used for protection circuits

1670