What is the difference between online ups and offline ups?
Answer Posted / sushant kumarj ena
Online UPS, it is getting power AC is converting to DC, then
the DC source stored to Battery at power supply on mode when
power fail, the DC sorce is changed to AC by inverter so
output power is having without noise.
OFFline UPS is having automatic voltage regulator, it
getting power from supply, it is regulated by AVR, then
power stored to battery so the change over time approx 2ms
to 5ms so change over noise comes.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to measure size of cable on a given load
Different STANDARDS (BS, IS, IEC etc) gives different informations on CT specification. How they correspons w r t each other (i.e I mean to say BS provides "knee point voltage" but IS does not, then how can i select CT)
Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?
While converting delta into star or star into delta ,the three values of resistances remains unchanged .Find out the value?Let In star R1=x;r2=x;R3=x On converting into delta,R12=x;R23=x;R31=x Find the value of x
how the inner and outer body is separated in aircrafts?
what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?
what is the importance of Partial Dischage test for Electrical Equipments
What is ST and specify its range of voltage.
what are inherent currents?
define the active power?
how to check ac servo motor
how we calculate torque ? how we improve it ?where torque will either motor or generator ?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
hi i will D.E.E.E.is completed pls send rrb diploma old qustion papaer sent in my e mail. i.d.
why most of junction box vendors providing T5/T6 Temp class jb's for T3 area any special reason?